Hoshizaki H-series ice machine Error Codes
Applies to: H-series stackable crescent cubers. Compiled and paraphrased from Hoshizaki America's own Service Manual for stackable crescent cubers, manual number 73208 (issued 7-7-2015, revised 8-11-2015), covering the KM-1301SAH/3, SWH/3 and SRH/3, KM-1400SWH-M and SWH3-M, KM-1601SAH/3, SWH/3 and SRH/3, KM-1900SAH/3, SWH/3 and SRH/3, KM-2100SWH3 and SRH3, KM-2500SWH3 and SRH3, and KMH-2000SWH/3 and SRH/3. The manual applies the same alarm table to both the E control board (2A1410-02) and the G control board (2A3792-01), and supplies the trigger values, cause lists, reset rules and LED meanings used here; this copy is the Hoshizaki manual as distributed through a dealer. The manual does not say whether ALARM RESET is needed after a 6- or 7-beep alarm, only that those clear automatically. Newer J-series KM machines use a different board and have their own table on this site, and modular H-series KM models have their own manuals; confirm against the manual for your exact model. Table last updated Nov 6, 2026.
Not your model? Other Hoshizaki code tables: FM-series flakers and F/FD modular flakers, KM crescent cubers, J series.
Machine down now? 16 companies in this directory name Hoshizaki on their own site, with who has been phone-confirmed and who covers nights. Or find an ice machine technician by city.
How to read the codes
Older Hoshizaki H-series crescent cubers report faults as BEEPS, repeated every 3 seconds, from either an E control board or a G control board. Every alarm shuts the ice machine down. Count the beeps. 1, 2 and 3 beeps need a MANUAL RESET: press the ALARM RESET button on the board with the power on, and the machine restarts with its 1-minute fill. 6 and 7 beeps are voltage protection and clear by themselves once the supply is right. Hoshizaki warns of ELECTRIC SHOCK when pressing the reset button while the board is beeping, so touch only the button, never the terminals around it. 2 and 3 beeps only trip after two bad cycles in a row, so a machine that keeps re-alarming after a reset has a real fault: call service rather than resetting it again and again.
The codes
| Code | Meaning | Likely causes | Operator-safe steps | Technician work |
|---|---|---|---|---|
| 1 beep | HIGH EVAPORATOR TEMPERATURE. The evaporator went above 127F (53C) and the ice machine has shut down | Hoshizaki's list: a harvest problem (a hot gas valve or relay stuck on), HOT WATER getting into the ice machine, or a shorted thermistor | Check the water supply to the ice machine is cold, not tied into a hot line. You can press ALARM RESET once with the power on. If it comes back, call service | Hot gas valve and relay, thermistor |
| 2 beeps | HARVEST BACKUP TIMER. Harvest ran longer than 20 MINUTES for TWO CYCLES IN A ROW and the ice machine has shut down | Hoshizaki's list: an open thermistor, the hot gas valve not opening, the expansion valve or liquid line valve leaking by, low refrigerant charge, a weak compressor, or the water regulating valve leaking by (water-cooled models). On the E board the orange H TIMER light is on | Press ALARM RESET once with the power on. Because it needs two bad cycles in a row to trip, a reset does not fix the cause. If it returns, call service | Thermistor, hot gas valve, refrigeration circuit |
| 3 beeps | FREEZE TIMER. Freeze ran longer than the freeze timer setting for TWO CYCLES IN A ROW and the ice machine has shut down | Hoshizaki's list: a float switch stuck closed, the inlet water valve leaking by, the hot gas valve leaking by, the water pump not pumping, the expansion valve not feeding, the liquid line valve not opening, low charge, the headmaster not bypassing (remote models), or a weak compressor. On the E board the yellow F TIMER light is on | Press ALARM RESET once with the power on. If it returns, call service. A dirty machine can make a float stick, so make sure cleaning is up to date | Float switch, valves, pump, refrigeration circuit |
| 6 beeps | LOW VOLTAGE. Control voltage at or below 92 VAC (plus or minus 5%). The red POWER OK light goes out | A supply problem, not an ice machine fault in itself | This one RESETS AUTOMATICALLY once the voltage is back to normal. If it keeps happening, have an electrician check the supply | Supply voltage and control transformer |
| 7 beeps | HIGH VOLTAGE. Control voltage at or above 147 VAC (plus or minus 5%). The red POWER OK light goes out | A supply problem | Resets automatically once the voltage is corrected. If it keeps happening, have an electrician check the supply | Supply voltage and control transformer |
| Red POWER OK light off | No control voltage, or the voltage protection above has operated | The red light shows control voltage is present at the board | Check the power is on. If beeping, see 6 and 7 beeps | Control transformer and supply |
| Yellow BC OPEN light (G board) | NOT A FAULT. The bin control is open: the bin is full | The G board shows bin control status with a green BC CLOSED and a yellow BC OPEN light. Yellow means the machine has stopped because the bin is full | Nothing, unless the bin is not actually full. Then check nothing is resting against the bin control | Bin control switch |
If this needs an ice machine technician
16 companies in this directory name Hoshizaki on their own site: that page shows who has been phone-confirmed, who publishes 24/7 cover, and what each puts in writing. Start there if the brand matters more than the city.
Two questions worth reading before you ring anyone: what to do first when a code appears and how to tell whether it is yours to fix.
Or browse ice machines service companies by state:
Indiana: Evansville · Fort Wayne · Indianapolis · South Bend
Kentucky: Bowling Green · Lexington · Louisville · Owensboro
Ohio: Akron · Canton · Cincinnati · Cleveland · Columbus · Dayton · Sandusky · Toledo · Upper Sandusky · Youngstown
Pennsylvania: Allentown · Altoona · Erie · Harrisburg · Lancaster · Pittsburgh · Scranton · Williamsport
West Virginia: Charleston · Martinsburg · Morgantown · Wheeling
Related: the PM checklist that prevents the most common codes outright, and the operator guides for symptom-first diagnosis.
Not sure this is the right make? The lookup by code shows every make that uses a given code, and flags the ones that mean different things depending on the machine in front of you.