Error Code Lookup, by Code
Every other page here is organised by brand, which assumes you know which make you are standing in front of. If you have a code and not a brand, start here. 430 codes from 42 manufacturers' service manuals.
102 of these codes mean different things on different makes. E1 is low ice production on a Hoshizaki, a cabinet probe failure on a True, and an air temperature sensor fault on a Hatco. Match the brand before you act on the meaning, or you will diagnose the wrong machine confidently.
Codes that mean more than one thing
These are the ones worth checking the badge on the machine first.
| Code | Make | Means |
|---|---|---|
| 000 | True T-series and GDM reach-ins | Probe open circuit and probe closed circuit respectively |
| Perlick BBS/SDB and HP-series units | Probe open circuit and probe closed circuit | |
| 1 | Scotsman Prodigy series cubers | Long freeze cycle. FLASHING means max freeze exceeded and retrying; STEADY means shut down |
| Scotsman Flaker/nugget machines | No ice sensed: retrying | |
| Scotsman Flaker/nugget machines | No ice sensed: shut down | |
| 1 BEEP | Hoshizaki FM-series flakers and F/FD modular flakers | Low water safety: the reservoir did not refill in time |
| Hoshizaki KM crescent cubers, J series | HIGH EVAPORATOR TEMPERATURE: above 127F (53C). Manual reset | |
| Hoshizaki H-series stackable crescent cubers | HIGH EVAPORATOR TEMPERATURE. The evaporator went above 127F (53C) and the ice machine has shut down | |
| 1 FLASH | Berkel X13 slicers | High temperature detected on the control board |
| Baxter OV500 rotating rack ovens | Air flow fault | |
| 2 | Scotsman Prodigy series cubers | Long harvest cycle. FLASHING means retrying; STEADY means shut down |
| Scotsman Flaker/nugget machines | Auger motor high load | |
| Middleby Marshall PS640 and PS540 conveyor ovens | PS640: NORMAL OPERATION. The oven is in an energy saving state | |
| 2 BEEPS | Hoshizaki FM-series flakers and F/FD modular flakers | Control switch left in DRAIN longer than 15 minutes |
| Hoshizaki KM crescent cubers, J series | HARVEST BACKUP TIMER: harvest longer than 20 MINUTES for TWO CYCLES IN A ROW. Manual reset | |
| Hoshizaki H-series stackable crescent cubers | HARVEST BACKUP TIMER. Harvest ran longer than 20 MINUTES for TWO CYCLES IN A ROW and the ice machine has shut down | |
| 2 FLASHES | Berkel X13 slicers | Overcurrent detected in the control board |
| Baxter OV500 rotating rack ovens | Flame fault with no call for heat | |
| 3 | Scotsman Prodigy series cubers | No water sensed |
| Scotsman Flaker/nugget machines | No water in reservoir | |
| Blodgett BCT and BLCT combis | Boiler high limit tripped: the boiler went above 275F | |
| Middleby Marshall PS640 and PS540 conveyor ovens | PS640: NORMAL OPERATION. The oven is in an energy saving state | |
| 3 BEEPS | Hoshizaki FM-series flakers and F/FD modular flakers | High-pressure switch tripped, first or second time within an hour |
| Hoshizaki KM crescent cubers, J series | FREEZE TIMER: freeze longer than the freeze timer setting for TWO CYCLES IN A ROW. Manual reset; the board shuts the icemaker down | |
| Hoshizaki H-series stackable crescent cubers | FREEZE TIMER. Freeze ran longer than the freeze timer setting for TWO CYCLES IN A ROW and the ice machine has shut down | |
| 3 FLASHES | Pitco Solstice and SG/SSH fryers | Temperature probe open or shorted |
| Berkel X13 slicers | Knife motor over temperature | |
| Baxter OV500 rotating rack ovens | Ignition module lockout after three failed trials for ignition | |
| 4 | Scotsman Prodigy series cubers | High discharge temperature |
| Scotsman Flaker/nugget machines | Refrigeration pressure too high or low | |
| Blodgett BCT and BLCT combis | Cavity overheat switch off: the oven chamber went above 662F | |
| 5 | Scotsman Prodigy series cubers | Sump temperature sensor failure |
| Blodgett BCT and BLCT combis | Fan motor above 248F | |
| 6 BEEPS | Hoshizaki FM-series flakers and F/FD modular flakers | Low supply voltage, at or below 92VAC plus or minus 5% |
| Hoshizaki H-series stackable crescent cubers | LOW VOLTAGE. Control voltage at or below 92 VAC (plus or minus 5%). The red POWER OK light goes out | |
| 7 | Scotsman Prodigy series cubers | Discharge temperature sensor failure |
| Blodgett BCT and BLCT combis | Oven chamber temperature probe broken. The oven cannot be used | |
| 7 BEEPS | Hoshizaki FM-series flakers and F/FD modular flakers | High supply voltage, at or above 147VAC plus or minus 5% |
| Hoshizaki H-series stackable crescent cubers | HIGH VOLTAGE. Control voltage at or above 147 VAC (plus or minus 5%). The red POWER OK light goes out | |
| 7 FLASHES | Pitco Solstice and SG/SSH fryers | Drain valve interlock open |
| Berkel X13 slicers | Unable to find home position | |
| 8 | Scotsman Prodigy series cubers | Short freeze, thin ice. FLASHING means retrying; STEADY means shut down |
| Blodgett BCT and BLCT combis | Core probe broken or not connected properly | |
| A1 | Turbo Air Reach-ins and Merchandisers | HIGH TEMPERATURE alarm. Corrected: this is not the door alarm |
| Heatcraft Beacon II Walk-In Systems | High box temperature alarm | |
| A2 | Turbo Air Reach-ins and Merchandisers | Low temperature alarm |
| Heatcraft Beacon II Walk-In Systems | Low box temperature alarm | |
| A4 | Turbo Air Reach-ins and Merchandisers | Door alarm. This is the code our table previously attributed to A1 |
| Heatcraft Beacon II Walk-In Systems | Input fault: box temperature, suction temperature or pressure transducer open or not installed | |
| AH1 | Perlick BBS/SDB and HP-series units | Eliwell controller: probe 1 high temperature alarm |
| Beverage-Air WTR, UCR and HF cabinets | Cabinet temperature too warm | |
| B | Scotsman Prodigy series cubers | The letters the display shows in normal operation |
| Scotsman Flaker/nugget machines | Bin full, ice making paused | |
| BLUE OFF | Gaylord CG3-UVi water-wash ventilators | One or more UV lamps are not working |
| Gaylord CG3-UVi water-wash ventilators | No power reaching the UV ballast | |
| C | Scotsman Prodigy series cubers | The letters the display shows in normal operation |
| Scotsman Flaker/nugget machines | Clean cycle running | |
| CA | True T-series and GDM reach-ins | External alarms of three severities, from a digital input |
| Perlick BBS/SDB and HP-series units | External alarms of three severities, from a digital input | |
| CCC | True T-series and GDM reach-ins | Probe open circuit and probe closed circuit respectively |
| Perlick BBS/SDB and HP-series units | Probe open circuit and probe closed circuit | |
| CLEAR CONVEYOR JAM | Hobart LXi/AM15 door dish machines | CL/CLe conveyor text alerts |
| Hobart CLeN rack conveyor dish machines | The conveyor motor OVERLOAD has tripped and shut the conveyor off | |
| D | Scotsman Prodigy series cubers | The letters the display shows in normal operation |
| Scotsman Flaker/nugget machines | Test mode active | |
| DEA | True T-series and GDM reach-ins | Defrost ended on TIME rather than on temperature |
| Perlick BBS/SDB and HP-series units | Defrost ended on TIME rather than on temperature | |
| DEF | True T-series and GDM reach-ins | Defrost in progress (LAE) |
| Beverage-Air WTR, UCR and HF cabinets | The unit is defrosting | |
| Heatcraft Beacon II Walk-In Systems | NOT FAULTS. These are the eight normal operating modes | |
| DOOR OPEN | Hobart LXi/AM15 door dish machines | CL/CLe conveyor text alerts |
| Hobart LXi/AM15 door dish machines | Door is open or not registering as closed | |
| Hobart CLeN rack conveyor dish machines | An inspection door is open | |
| Traulsen Intela-Traul reach-ins | Door open: a door has been open longer than the control allows | |
| E | Scotsman Prodigy series cubers | Self test failed at power-up, and nothing else will happen |
| Scotsman Flaker/nugget machines | Controller self test failed | |
| Stero SD3 door-type dish machines | The control keeps the most recent machine fault in service diagnostics even after a power cycle clears the display | |
| E0 | Hoshizaki FM-series flakers and F/FD modular flakers | Ice making water leak |
| Hobart LXi/AM15 door dish machines | Machine will not fill, or will not fill high enough. The cycle stops and the machine will not run | |
| E01 | Manitowoc Indigo/NXT/NEO cubers | Long freeze cycle |
| Alto-Shaam Combitherm combi ovens | Steam generator water fill fault | |
| Beverage-Air WTR, UCR and HF cabinets | Sensor S1 has failed, short or open. S1 is the air temperature probe | |
| E1 | Hoshizaki FM-series flakers and F/FD modular flakers | Low ice production |
| True T-series and GDM reach-ins | Cabinet temperature probe failure | |
| Perlick BBS/SDB and HP-series units | Probe reading out of range | |
| Beverage-Air WTR, UCR and HF cabinets | Sensor S1 has failed, short or open. S1 is the air temperature probe | |
| Hatco Flav-R-Savor holding cabinets | Air temperature sensor malfunctioning ON HOLDING CABINETS. On a Hydro-Heater it means something different: see below | |
| Turbo Air Reach-ins and Merchandisers | Depends entirely on which controller is fitted, and published sources contradict each other | |
| Heatcraft Beacon II Walk-In Systems | Sensor shorted, open or not installed: room, defrost and suction respectively | |
| E02 | Manitowoc Indigo/NXT/NEO cubers | Long harvest cycle |
| Alto-Shaam Combitherm combi ovens | Control temperature high (CTP/CTC) | |
| Beverage-Air WTR, UCR and HF cabinets | Sensor S2 has failed, short or open. S2 is the evaporator coil probe used to terminate defrost | |
| E2 | Hoshizaki FM-series flakers and F/FD modular flakers | Float switch error |
| Hobart LXi/AM15 door dish machines | Machine will not fill, or will not fill high enough. The cycle stops and the machine will not run | |
| Hobart LXi/AM15 door dish machines | Fill did not complete: water failed to reach the tank float within 2.5 minutes (AM Select) | |
| True T-series and GDM reach-ins | Evaporator probe failure | |
| Perlick BBS/SDB and HP-series units | Defrost probe and third probe faulty | |
| Stero SD3 door-type dish machines | Water did not reach the float during fill within 150 seconds | |
| Beverage-Air WTR, UCR and HF cabinets | Sensor S2 has failed, short or open. S2 is the evaporator coil probe used to terminate defrost | |
| Hatco Flav-R-Savor holding cabinets | Humidity temperature sensor malfunctioning ON HOLDING CABINETS. On a Hydro-Heater it is the control probe: see below | |
| Turbo Air Reach-ins and Merchandisers | The clearest example of the contradiction, and worth checking carefully | |
| Heatcraft Beacon II Walk-In Systems | Sensor shorted, open or not installed: room, defrost and suction respectively | |
| E03 | Manitowoc Indigo/NXT/NEO cubers | Input power loss |
| Frymaster M3000 controller fryers | Temperature probe failure | |
| Alto-Shaam Combitherm combi ovens | Fan motor error (CTP/CTC) | |
| Beverage-Air WTR, UCR and HF cabinets | Sensor S3 has failed, short or open | |
| E3 | Hoshizaki FM-series flakers and F/FD modular flakers | Gear motor error or gear motor sensor circuit open |
| Hobart LXi/AM15 door dish machines | Machine will not fill, or will not fill high enough. The cycle stops and the machine will not run | |
| True T-series and GDM reach-ins | Auxiliary or display probe failure | |
| Perlick BBS/SDB and HP-series units | Defrost probe and third probe faulty | |
| Beverage-Air WTR, UCR and HF cabinets | Sensor S3 has failed, short or open | |
| Hatco Flav-R-Savor holding cabinets | The low water probe has not been satisfied and the heating elements are not yet submersed | |
| Heatcraft Beacon II Walk-In Systems | Sensor shorted, open or not installed: room, defrost and suction respectively | |
| E04 | Manitowoc Indigo/NXT/NEO cubers | High condenser temperature or water condenser fault |
| Frymaster M3000 controller fryers | High limit reading out of range | |
| Alto-Shaam Combitherm combi ovens | Lower fan motor error, two-motor models (CTP/CTC) | |
| Beverage-Air WTR, UCR and HF cabinets | Sensor S4 has failed, short or open | |
| E4 | Hoshizaki FM-series flakers and F/FD modular flakers | Abnormal high side pressure |
| Hobart LXi/AM15 door dish machines | Machine will not fill, or will not fill high enough. The cycle stops and the machine will not run | |
| Beverage-Air WTR, UCR and HF cabinets | Sensor S4 has failed, short or open | |
| Heatcraft Beacon II Walk-In Systems | Suction pressure transducer shorted, open or not installed | |
| E05 | Manitowoc Indigo/NXT/NEO cubers | High-pressure control opened |
| Frymaster M3000 controller fryers | High limit temperature exceeded | |
| Alto-Shaam Combitherm combi ovens | VFD communication failure (CTP/CTC) | |
| E5 | Hoshizaki FM-series flakers and F/FD modular flakers | Gear motor drive element error |
| Hobart LXi/AM15 door dish machines | Machine will not drain, or is filling too high and leaking from the door | |
| Heatcraft Beacon II Walk-In Systems | Outdoor temperature sensor shorted | |
| E06 | Frymaster M3000 controller fryers | Heating failure |
| Alto-Shaam Combitherm combi ovens | VFD communication failure, second drive (CTP/CTC) | |
| E6 | Hobart LXi/AM15 door dish machines | Control fault with no operator remedy published (AM Select) |
| Stero SD3 door-type dish machines | The float and temperature thermistors could not be detected at all | |
| Turbo Air Reach-ins and Merchandisers | Fault in the real-time clock | |
| Heatcraft Beacon II Walk-In Systems | Low superheat during cooling, held at 0F for two minutes | |
| E7 | Hobart LXi/AM15 door dish machines | Water sensors need cleaning |
| Heatcraft Beacon II Walk-In Systems | Compressor shutdown on a safety: high pressure, low pressure or oil pressure | |
| E08 | Manitowoc Indigo/NXT/NEO cubers | TXV fault |
| Frymaster M3000 controller fryers | ATO board error: the controller has lost contact with the automatic top-off board | |
| E09 | Manitowoc Indigo/NXT/NEO cubers | Flooding evaporator TXV fault |
| Frymaster M3000 controller fryers | Top-off pump not filling | |
| E10 | Manitowoc Indigo/NXT/NEO cubers | Flooding evaporator TXV fault |
| Frymaster M3000 controller fryers | Drain valve not open | |
| E11 | Manitowoc Indigo/NXT/NEO cubers | Refrigeration fault |
| Frymaster M3000 controller fryers | Drain valve not closed | |
| E12 | Manitowoc Indigo/NXT/NEO cubers | Curtain switch open more than 24 hours |
| Frymaster M3000 controller fryers | Return valve not open | |
| E16 | Manitowoc Indigo/NXT/NEO cubers | Remote condenser fault |
| Frymaster M3000 controller fryers | Filtration (AIF) probe error | |
| E20 | Manitowoc Indigo/NXT/NEO cubers | Water system fault |
| Frymaster M3000 controller fryers | Invalid code location: the SD card was removed during a software upgrade | |
| E25 | Manitowoc Indigo/NXT/NEO cubers | Bin level probe low sensor fault |
| Frymaster M3000 controller fryers | Recovery fault | |
| E27 | Manitowoc Indigo/NXT/NEO cubers | Bin level probe fault, medium (E26) and high (E27) sensor |
| Frymaster M3000 controller fryers | Low temperature alarm: oil is roughly 35F below setpoint | |
| Turbo Air Reach-ins and Merchandisers | Sensor errors on specific inputs: S5, Sair and Saux respectively | |
| E28 | Manitowoc Indigo/NXT/NEO cubers | AUCS board not detected |
| Frymaster M3000 controller fryers | High temperature alarm | |
| E29 | Manitowoc Indigo/NXT/NEO cubers | USB communication or download fault |
| Turbo Air Reach-ins and Merchandisers | Sensor errors on specific inputs: S5, Sair and Saux respectively | |
| E30 | Manitowoc Indigo/NXT/NEO cubers | USB communication or download fault |
| Turbo Air Reach-ins and Merchandisers | Sensor errors on specific inputs: S5, Sair and Saux respectively | |
| E105 | Alto-Shaam Combitherm combi ovens | Low water pressure or no water |
| Merrychef eikon speed ovens | Supply voltage high or low, OR supply frequency high or low, depending on the model | |
| EA | True T-series and GDM reach-ins | External alarms of three severities, from a digital input |
| Perlick BBS/SDB and HP-series units | External alarms of three severities, from a digital input | |
| ED | Hobart LXi/AM15 door dish machines | Slow leak: the tank is losing water (AM Select) |
| Stero SD3 door-type dish machines | Slow leak: the machine refilled three times within 35 minutes of the initial fill | |
| EE | Hobart LXi/AM15 door dish machines | Final rinse never reached temperature: the booster did not hit setpoint within 8 minutes after initial fill (AM Select) |
| True T-series and GDM reach-ins | Power interruption during fast chill, clock settings lost, memory corruption | |
| Stero SD3 door-type dish machines | The booster did not reach temperature within eight minutes of the initial fill | |
| F | Scotsman Prodigy series cubers | The letters the display shows in normal operation |
| Scotsman Flaker/nugget machines | Freeze mode: the machine is making ice | |
| Stero SD3 door-type dish machines | The control keeps the most recent machine fault in service diagnostics even after a power cycle clears the display | |
| F1 | TurboChef Tornado rapid cook ovens | Blower running status bad |
| Jackson NXP door-type dish machines | The booster is calling for heat with no water in it, which the control blocks to protect the element | |
| Turbo Air Reach-ins and Merchandisers | F-sensor and D-sensor malfunction respectively | |
| F2 | TurboChef Tornado rapid cook ovens | Cook temperature low |
| Jackson NXP door-type dish machines | A heater contactor is not switching off when it should | |
| F3 | TurboChef Tornado rapid cook ovens | Magnetron current low |
| Jackson NXP door-type dish machines | The machine could not fill | |
| F4 | TurboChef Tornado rapid cook ovens | Door monitor defective |
| Jackson NXP door-type dish machines | The machine is not receiving power correctly | |
| F5 | TurboChef Tornado rapid cook ovens | Magnetron over temperature |
| Jackson NXP door-type dish machines | The tank is not reaching temperature | |
| F6 | TurboChef Tornado rapid cook ovens | Electrical compartment temperature high |
| Jackson NXP door-type dish machines | Same fault as F1 but on the wash tank rather than the booster | |
| F7 | TurboChef Tornado rapid cook ovens | Thermocouple open |
| TurboChef Tornado rapid cook ovens | Two codes display on screen but are never counted, so the log understates what the oven has been doing | |
| Jackson NXP door-type dish machines | A heater contactor is not switching off when it should | |
| F8 | TurboChef Tornado rapid cook ovens | Heat low fault |
| Jackson NXP door-type dish machines | The machine could not fill | |
| GREEN OFF | Gaylord CG3-UVi water-wash ventilators | UV system in standby and not operating |
| Gaylord CG3-UVi water-wash ventilators | No power reaching the UV ballast | |
| HA | True T-series and GDM reach-ins | thi: highest temperature recorded in the LAE log. HA: live high temperature alarm on Dixell models |
| Perlick BBS/SDB and HP-series units | Dixell controller: maximum temperature alarm | |
| HI | True T-series and GDM reach-ins | Cabinet high temperature alarm (LAE) |
| Vulcan VK/TR and ER/GR fryers | Oil at 415F or above | |
| Pitco Solstice and SG/SSH fryers | Oil at an unsafe temperature | |
| Beverage-Air WTR, UCR and HF cabinets | Cabinet temperature too warm | |
| HI TEMP | Frymaster M3000 controller fryers | Three separate over-temperature messages that are easy to confuse |
| Garland MCO convection ovens | The oven is more than 50F above its setpoint, and the heaters have been cut | |
| L | Scotsman Prodigy series cubers | The letters the display shows in normal operation |
| Scotsman Flaker/nugget machines | Board locked, buttons ignored | |
| LA | True T-series and GDM reach-ins | tLo: lowest temperature recorded in the LAE log. LA: live low temperature alarm on Dixell models |
| Perlick BBS/SDB and HP-series units | Dixell controller: minimum temperature alarm | |
| LO | True T-series and GDM reach-ins | Cabinet low temperature alarm (LAE) |
| Pitco Solstice and SG/SSH fryers | Oil below the ready temperature | |
| Beverage-Air WTR, UCR and HF cabinets | Cabinet temperature too cold | |
| LOC | True T-series and GDM reach-ins | Keypad locked (LAE) |
| Heatcraft Beacon II Walk-In Systems | Not a fault. The board is locked and settings cannot be changed | |
| O | Scotsman Prodigy series cubers | The letters the display shows in normal operation |
| Scotsman Flaker/nugget machines | Machine switched off at the controller | |
| OFF | True T-series and GDM reach-ins | Controller in standby, refrigeration off (LAE) |
| True T-series and GDM reach-ins | External alarms of three severities, from a digital input | |
| Perlick BBS/SDB and HP-series units | External alarms of three severities, from a digital input | |
| Garland MCO convection ovens | Not a fault. The oven is off and has cooled below 150F, so the fan relay has opened | |
| Heatcraft Beacon II Walk-In Systems | NOT FAULTS. These are the eight normal operating modes | |
| OPEN PROBE | Vulcan VK/TR and ER/GR fryers | Temperature probe circuit open |
| Southbend Convection Oven | The RTD temperature probe reads open | |
| P1 | Hobart LXi/AM15 door dish machines | Tank temperature probe out of range |
| True T-series and GDM reach-ins | Cabinet temperature probe failure | |
| Perlick BBS/SDB and HP-series units | Dixell controller: probe failure | |
| Stero SD3 door-type dish machines | Wash tank thermistor open or shorted | |
| P2 | Hobart LXi/AM15 door dish machines | Tank temperature probe out of range |
| True T-series and GDM reach-ins | Evaporator probe failure | |
| Stero SD3 door-type dish machines | Rinse thermistor open or shorted | |
| P3 | Hobart LXi/AM15 door dish machines | Rinse temperature probe out of range |
| True T-series and GDM reach-ins | Auxiliary or display probe failure | |
| Stero SD3 door-type dish machines | Booster thermistor open or shorted | |
| SERVICE 10 | Rational SCC series combi ovens | Self-clean water not pumped out |
| Rational iCombi Pro and Classic | SC automation malfunctioning (Classic title: SC-automatic failed). Cooking still possible | |
| SERVICE 11 | Rational SCC series combi ovens | Water metering sensor over-reading during steam generator fill |
| Rational iCombi Pro and Classic | Steam generator water intake malfunctioning (Classic: Water supply steam generator failed). Cooking still possible | |
| SERVICE 12 | Rational SCC series combi ovens | CDS sensor giving no output signal |
| Rational iCombi Pro and Classic | Water measurement system malfunctioning (Classic: Water volume measurement failed). Cooking still possible | |
| SERVICE 13 | Rational SCC series combi ovens | Steam generator not refilling during steam mode |
| Rational iCombi Pro and Classic | Steam generator water level detection malfunctioning (Classic: Water detection failed). ONLY HOT AIR MODE available | |
| SERVICE 17 | Rational SCC series combi ovens | External EEPROM faulty |
| Rational iCombi Pro and Classic | Unit model incorrect (Classic: Unit data failed). NO cooking | |
| SERVICE 25 | Rational SCC series combi ovens | No water flow detected during CleanJet |
| Rational iCombi Pro and Classic | Water quantity required by the iCareSystem is too low (iCombi Pro) | |
| SERVICE 26 | Rational SCC series combi ovens | Drain valve permanently closed |
| Rational iCombi Pro and Classic | Cleaning ball valve cannot find its OPEN (26) or CLOSED (27) position (iCombi Pro). NO cooking | |
| SERVICE 27 | Rational SCC series combi ovens | Drain valve will not close, CleanJet unavailable |
| Rational iCombi Pro and Classic | Cleaning ball valve cannot find its OPEN (26) or CLOSED (27) position (iCombi Pro). NO cooking | |
| SERVICE 29 | Rational SCC series combi ovens | Control board over temperature |
| Rational iCombi Pro and Classic | Board temperature too high (Classic: Electric compartment too hot). NO cooking | |
| SERVICE 30 | Rational SCC series combi ovens | Running in emergency humidity control |
| Rational iCombi Pro and Classic | Humidity measurement incorrect (Classic: Humidity control failed). Cooking still possible | |
| SERVICE 34.X | Rational SCC series combi ovens | Bus signal error, with the digit naming the device |
| Rational iCombi Pro and Classic | Internal data communication faulty; the suffix sets how serious it is | |
| SERVICE 36 | Rational SCC series combi ovens | Differential pressure sensor P1 faulty or out of range |
| Rational iCombi Pro and Classic | Differential pressure sensor defective. Cooking still possible | |
| SERVICE 37 | Rational SCC series combi ovens | Differential pressure sensor P1 faulty or out of range |
| Rational iCombi Pro and Classic | Differential pressure sensor defective. Cooking still possible | |
| SERVICE 40 | Rational SCC series combi ovens | Care Control fault |
| Rational iCombi Pro and Classic | Care liquid quantity required by the iCareSystem is too low (iCombi Pro). Cooking still possible | |
| SHORTED PROBE | Vulcan VK/TR and ER/GR fryers | Temperature probe shorted |
| Southbend Convection Oven | The RTD temperature probe reads shorted | |
| TEMP SENSOR OUT OF RANGE | Bunn Axiom and Infusion Series ICB digital-control brewers | The temperature sensor circuit reads open |
| Bunn Axiom and Infusion Series ICB digital-control brewers | The temperature sensor circuit reads shorted | |
| YELLOW ON | Gaylord CG3-UVi water-wash ventilators | One or more UV lamps are not working |
| Gaylord CG3-UVi water-wash ventilators | No power reaching the UV ballast |
Every code, A to Z
| Code | Make | Means |
|---|---|---|
| 000 | True T-series and GDM reach-ins | Probe open circuit and probe closed circuit respectively |
| Perlick BBS/SDB and HP-series units | Probe open circuit and probe closed circuit | |
| 1 | Scotsman Prodigy series cubers | Long freeze cycle. FLASHING means max freeze exceeded and retrying; STEADY means shut down |
| Scotsman Flaker/nugget machines | No ice sensed: retrying | |
| Scotsman Flaker/nugget machines | No ice sensed: shut down | |
| 001 | Hobart AM16 door-type dish machines | Booster thermistor error: Drain Machine, Call Service |
| 1 BEEP | Hoshizaki FM-series flakers and F/FD modular flakers | Low water safety: the reservoir did not refill in time |
| Hoshizaki KM crescent cubers, J series | HIGH EVAPORATOR TEMPERATURE: above 127F (53C). Manual reset | |
| Hoshizaki H-series stackable crescent cubers | HIGH EVAPORATOR TEMPERATURE. The evaporator went above 127F (53C) and the ice machine has shut down | |
| 1 FLASH | Berkel X13 slicers | High temperature detected on the control board |
| Baxter OV500 rotating rack ovens | Air flow fault | |
| 2 | Scotsman Prodigy series cubers | Long harvest cycle. FLASHING means retrying; STEADY means shut down |
| Scotsman Flaker/nugget machines | Auger motor high load | |
| Middleby Marshall PS640 and PS540 conveyor ovens | PS640: NORMAL OPERATION. The oven is in an energy saving state | |
| 002 | Hobart AM16 door-type dish machines | Booster thermistor error: Drain Machine, Call Service |
| 2 BEEPS | Hoshizaki FM-series flakers and F/FD modular flakers | Control switch left in DRAIN longer than 15 minutes |
| Hoshizaki KM crescent cubers, J series | HARVEST BACKUP TIMER: harvest longer than 20 MINUTES for TWO CYCLES IN A ROW. Manual reset | |
| Hoshizaki H-series stackable crescent cubers | HARVEST BACKUP TIMER. Harvest ran longer than 20 MINUTES for TWO CYCLES IN A ROW and the ice machine has shut down | |
| 2 FLASHES | Berkel X13 slicers | Overcurrent detected in the control board |
| Baxter OV500 rotating rack ovens | Flame fault with no call for heat | |
| 2 OR 3 | Stero SD3 door-type dish machines | The control's record of which thermistor faulted |
| 2 OR 6 | Stero SD3 door-type dish machines | The control keeps the most recent machine fault in service diagnostics even after a power cycle clears the display |
| 3 | Scotsman Prodigy series cubers | No water sensed |
| Scotsman Flaker/nugget machines | No water in reservoir | |
| Blodgett BCT and BLCT combis | Boiler high limit tripped: the boiler went above 275F | |
| Middleby Marshall PS640 and PS540 conveyor ovens | PS640: NORMAL OPERATION. The oven is in an energy saving state | |
| 003 | Hobart AM16 door-type dish machines | Booster temperature not reached during the FILL (003) or WASH (004) cycle |
| 3 BEEPS | Hoshizaki FM-series flakers and F/FD modular flakers | High-pressure switch tripped, first or second time within an hour |
| Hoshizaki KM crescent cubers, J series | FREEZE TIMER: freeze longer than the freeze timer setting for TWO CYCLES IN A ROW. Manual reset; the board shuts the icemaker down | |
| Hoshizaki H-series stackable crescent cubers | FREEZE TIMER. Freeze ran longer than the freeze timer setting for TWO CYCLES IN A ROW and the ice machine has shut down | |
| 3 FLASHES | Pitco Solstice and SG/SSH fryers | Temperature probe open or shorted |
| Berkel X13 slicers | Knife motor over temperature | |
| Baxter OV500 rotating rack ovens | Ignition module lockout after three failed trials for ignition | |
| 4 | Scotsman Prodigy series cubers | High discharge temperature |
| Scotsman Flaker/nugget machines | Refrigeration pressure too high or low | |
| Blodgett BCT and BLCT combis | Cavity overheat switch off: the oven chamber went above 662F | |
| 004 | Hobart AM16 door-type dish machines | Booster temperature not reached during the FILL (003) or WASH (004) cycle |
| 4 BEEPS | Hoshizaki FM-series flakers and F/FD modular flakers | High-pressure switch tripped a third time within the same hour |
| 4 FLASHES | Berkel X13 slicers | Automatic motor internal hall effect malfunction |
| 4 TO 10 | Turbo Air Reach-ins and Merchandisers | Not equipment faults at all: results of copying settings with a copy key |
| 5 | Scotsman Prodigy series cubers | Sump temperature sensor failure |
| Blodgett BCT and BLCT combis | Fan motor above 248F | |
| 5 BEEPS | Hoshizaki FM-series flakers and F/FD modular flakers | Freeze timer: 30 minutes elapsed without the lower float opening |
| 5 FLASHES | Berkel X13 slicers | Automatic motor hall effect transition malfunction |
| 006 | Hobart AM16 door-type dish machines | Sump thermistor error: Drain Machine, Call Service |
| 6 | Blodgett BCT and BLCT combis | Drain temperature above 167F for more than five minutes, against a normal below 140F |
| 6 BEEPS | Hoshizaki FM-series flakers and F/FD modular flakers | Low supply voltage, at or below 92VAC plus or minus 5% |
| Hoshizaki H-series stackable crescent cubers | LOW VOLTAGE. Control voltage at or below 92 VAC (plus or minus 5%). The red POWER OK light goes out | |
| 6 FLASHES | Berkel X13 slicers | Encoder input not active |
| 7 | Scotsman Prodigy series cubers | Discharge temperature sensor failure |
| Blodgett BCT and BLCT combis | Oven chamber temperature probe broken. The oven cannot be used | |
| 007 | Hobart AM16 door-type dish machines | Sump thermistor error: Drain Machine, Call Service |
| 7 BEEPS | Hoshizaki FM-series flakers and F/FD modular flakers | High supply voltage, at or above 147VAC plus or minus 5% |
| Hoshizaki H-series stackable crescent cubers | HIGH VOLTAGE. Control voltage at or above 147 VAC (plus or minus 5%). The red POWER OK light goes out | |
| 7 FLASHES | Pitco Solstice and SG/SSH fryers | Drain valve interlock open |
| Berkel X13 slicers | Unable to find home position | |
| 8 | Scotsman Prodigy series cubers | Short freeze, thin ice. FLASHING means retrying; STEADY means shut down |
| Blodgett BCT and BLCT combis | Core probe broken or not connected properly | |
| 008 | Hobart AM16 door-type dish machines | Wash tank temperature not reached during the fill cycle |
| 8 BEEPS | Hoshizaki FM-series flakers and F/FD modular flakers | Gear motor alarm: the compressor control relay contacts failed to close |
| 8 FLASHES | Berkel X13 slicers | Carriage moving too fast or too slow |
| 9 | Blodgett BCT and BLCT combis | Boiler probe (9) or drain probe (10) not working properly |
| 9 BEEPS | Hoshizaki FM-series flakers and F/FD modular flakers | Bin control fault: the mechanical backup had to stop the machine |
| 9 FLASHES | Berkel X13 slicers | Clutch disengaged while running |
| 10 | Blodgett BCT and BLCT combis | Boiler probe (9) or drain probe (10) not working properly |
| 10 FLASHES | Berkel X13 slicers | Slide bar guide switch not engaged |
| 11 | Blodgett BCT and BLCT combis | Not enough water: the steam generator did not fill to high level within two minutes |
| 12 | Blodgett BCT and BLCT combis | Solid state relay heat sink above 248F |
| 13 | Blodgett BCT and BLCT combis | Top heating element of the steam generator above 266F |
| 014 | Hobart AM16 door-type dish machines | Booster pressure error: Drain Machine, Call Service |
| 14 | Blodgett BCT and BLCT combis | Fan rotational speed too slow |
| 015 | Hobart AM16 door-type dish machines | Booster pressure error: Drain Machine, Call Service |
| 15 | Blodgett BCT and BLCT combis | CPU board (15) or IO board (16) above 140F |
| 016 | Hobart AM16 door-type dish machines | Wash tank pressure error: Drain Machine, Call Service |
| 16 | Blodgett BCT and BLCT combis | CPU board (15) or IO board (16) above 140F |
| 017 | Hobart AM16 door-type dish machines | Wash tank pressure error: Drain Machine, Call Service |
| 018 | Hobart AM16 door-type dish machines | Wash tank water level too high. Machine draining |
| 020 | Hobart AM16 door-type dish machines | Rinse system error: Check and Clean Rinse Arms |
| 20 | Blodgett BCT and BLCT combis | Communication failure between the computer and the IO board |
| 20.2 | Rational iCombi Pro and Classic | A temperature probe is defective; the suffix says which one |
| 20.4 | Rational iCombi Pro and Classic | A temperature probe is defective; the suffix says which one |
| 20.8 | Rational iCombi Pro and Classic | A temperature probe is defective; the suffix says which one |
| 021 | Hobart AM16 door-type dish machines | Drain hose is clogged: clean drain hose and drain machine again |
| 022 | Hobart AM16 door-type dish machines | Drain system error during wash program |
| 22 | Blodgett BCT and BLCT combis | Program interrupted by a power outage long enough that it cannot restart |
| 023 | Hobart AM16 door-type dish machines | Rapid fill timeout: inspect incoming water line (rapid fill kit units) |
| 23 | Blodgett BCT and BLCT combis | The oven is too hot for CombiWash to start |
| 24 | Blodgett BCT and BLCT combis | Drain blocked: the steam generator could not be emptied during flushing |
| 25 | Blodgett BCT and BLCT combis | ClimaOptima humidity faults: not calibrated (25), sensor out of range (26), or calibration did not complete (27) |
| 26 | Blodgett BCT and BLCT combis | ClimaOptima humidity faults: not calibrated (25), sensor out of range (26), or calibration did not complete (27) |
| 27 | Blodgett BCT and BLCT combis | ClimaOptima humidity faults: not calibrated (25), sensor out of range (26), or calibration did not complete (27) |
| 28.2 | Rational iCombi Pro and Classic | Temperature limit exceeded: steam generator (28.1), cooking cabinet (28.2), or 28.4 as described |
| 28.4 | Rational iCombi Pro and Classic | Temperature limit exceeded: steam generator (28.1), cooking cabinet (28.2), or 28.4 as described |
| 029 | Hobart AM16 door-type dish machines | Door opened: Program interrupted (029) or Fill cycle interrupted (039). Close door |
| 29 | Blodgett BCT and BLCT combis | Door sensor not working properly |
| 31.2 | Rational iCombi Pro and Classic | Core temperature probe defective. Cooking possible WITHOUT the probe |
| 032 | Hobart AM16 door-type dish machines | Fill error: inspect incoming water line |
| 033 | Hobart AM16 door-type dish machines | Booster fill error: check incoming water line and shut-off valve |
| 33.1-33.3 | Rational iCombi Pro and Classic | Gas burner faulty (gas units). NO cooking |
| 34 | Blodgett BCT and BLCT combis | Water pressure too low |
| 035 | Hobart AM16 door-type dish machines | Ensure tank strainer is locked in place |
| 37 | Blodgett BCT and BLCT combis | CombiWash could not cool to set point (37), or was interrupted with detergent still in the chamber (38) |
| 038 | Hobart AM16 door-type dish machines | Incoming power too high: machine has powered down |
| 38 | Blodgett BCT and BLCT combis | CombiWash could not cool to set point (37), or was interrupted with detergent still in the chamber (38) |
| 039 | Hobart AM16 door-type dish machines | Door opened: Program interrupted (029) or Fill cycle interrupted (039). Close door |
| 45 | Blodgett BCT and BLCT combis | No 24VAC: the main contactor output is not working |
| 46.2 | Rational iCombi Pro and Classic | Water supply malfunctioning, steam generator (Classic title: Pump failed). Cooking still possible |
| 47.2 | Rational iCombi Pro and Classic | Waste water pump defective. Cooking still possible |
| 48.2 | Rational iCombi Pro and Classic | Circulating pump defective (iCombi Pro). Cooking still possible |
| 049 | Hobart AM16 door-type dish machines | Communication between the controls has been interrupted |
| 49.2 | Rational iCombi Pro and Classic | Water supply faulty, care system (Classic title: Pump failed). Cooking still possible |
| 50 | Blodgett BCT and BLCT combis | Pressure switch errors: active at start when it should not be (50/60), or not active once the gas fan runs (51/61) |
| 51 | Blodgett BCT and BLCT combis | Pressure switch errors: active at start when it should not be (50/60), or not active once the gas fan runs (51/61) |
| 052 | Hobart AM16 door-type dish machines | Drain system error: check drain pump and hose |
| 52 | Blodgett BCT and BLCT combis | Gas valve failure: the valve did not open after five start attempts |
| 52.2 | Rational iCombi Pro and Classic | Cooking cabinet lighting not working correctly (Classic: Cabinet light failed). Cooking still possible |
| 054 | Hobart AM16 door-type dish machines | ASR strainer basket not detected (ASR models) |
| 54 | Blodgett BCT and BLCT combis | Gas fan RPM incorrect before ignition |
| 55 | Blodgett BCT and BLCT combis | Ignition failure on first attempt, a WARNING only (55/65), or no flame detected after five attempts (56/66) |
| 56 | Blodgett BCT and BLCT combis | Ignition failure on first attempt, a WARNING only (55/65), or no flame detected after five attempts (56/66) |
| 057 | Hobart AM16 door-type dish machines | Wash tank is filling: cycle will begin when water is replenished |
| 57 | Blodgett BCT and BLCT combis | Gas stopped during operation. Warning only |
| 60 | Blodgett BCT and BLCT combis | Pressure switch errors: active at start when it should not be (50/60), or not active once the gas fan runs (51/61) |
| 61 | Blodgett BCT and BLCT combis | Pressure switch errors: active at start when it should not be (50/60), or not active once the gas fan runs (51/61) |
| 62 | Blodgett BCT and BLCT combis | Gas valve failure: the valve did not open after five start attempts |
| 64 | Blodgett BCT and BLCT combis | Gas fan RPM incorrect before ignition |
| 65 | Blodgett BCT and BLCT combis | Ignition failure on first attempt, a WARNING only (55/65), or no flame detected after five attempts (56/66) |
| 66 | Blodgett BCT and BLCT combis | Ignition failure on first attempt, a WARNING only (55/65), or no flame detected after five attempts (56/66) |
| 67 | Blodgett BCT and BLCT combis | Gas stopped during operation. Warning only |
| 075 | Hobart AM16 door-type dish machines | Rinse aid empty: refill rinse aid |
| 077 | Hobart AM16 door-type dish machines | Detergent empty: MACHINE LOCKED |
| 079 | Hobart AM16 door-type dish machines | Sanitizer empty: MACHINE LOCKED (SCB models) |
| 081 | Hobart AM16 door-type dish machines | Final rinse thermistor error |
| 082 | Hobart AM16 door-type dish machines | Final rinse thermistor error |
| 084 | Hobart AM16 door-type dish machines | Minimum final rinse temperature not reached: MACHINE LOCKED (SCB models) |
| 085 | Hobart AM16 door-type dish machines | Wash tank overtemp tripped |
| 086 | Hobart AM16 door-type dish machines | Booster overtemp tripped |
| 087 | Hobart AM16 door-type dish machines | Minimum final rinse temperature not reached after repeating cycle |
| 088 | Hobart AM16 door-type dish machines | Wash tank (088) or booster (089) CONTACTOR FAULT: Pull Circuit Breaker(s) and Contact Service |
| 089 | Hobart AM16 door-type dish machines | Wash tank (088) or booster (089) CONTACTOR FAULT: Pull Circuit Breaker(s) and Contact Service |
| 090 | Hobart AM16 door-type dish machines | Wash temperature not reached: drain and restart machine |
| 888 ON THE DISPLAY | Heatcraft Beacon II Walk-In Systems | Supply voltage has fallen below 18 VAC |
| 6100XL | Delfield MCII Tempatrol, and 6000XL/6100XL reach-ins | The display swaps the temperature read-out for an error read-out |
| A1 | Turbo Air Reach-ins and Merchandisers | HIGH TEMPERATURE alarm. Corrected: this is not the door alarm |
| Heatcraft Beacon II Walk-In Systems | High box temperature alarm | |
| A2 | Turbo Air Reach-ins and Merchandisers | Low temperature alarm |
| Heatcraft Beacon II Walk-In Systems | Low box temperature alarm | |
| A3 | Heatcraft Beacon II Walk-In Systems | System start-up failure: the compressor tried four times and failed |
| A4 | Turbo Air Reach-ins and Merchandisers | Door alarm. This is the code our table previously attributed to A1 |
| Heatcraft Beacon II Walk-In Systems | Input fault: box temperature, suction temperature or pressure transducer open or not installed | |
| A45 | Turbo Air Reach-ins and Merchandisers | NOT FAULTS: standby and case cleaning |
| A59 | Turbo Air Reach-ins and Merchandisers | NOT FAULTS: standby and case cleaning |
| A61 | Turbo Air Reach-ins and Merchandisers | Condenser temperature alarm |
| AH1 | Perlick BBS/SDB and HP-series units | Eliwell controller: probe 1 high temperature alarm |
| Beverage-Air WTR, UCR and HF cabinets | Cabinet temperature too warm | |
| AL1 | Perlick BBS/SDB and HP-series units | Eliwell controller: probe 1 low temperature alarm |
| ALM 1 | Middleby Marshall PS640 and PS540 conveyor ovens | PS540: HIGH-LIMIT alarm. The oven reached 650F (343C) |
| AUTO | Garland MCO convection ovens | Not a fault. The oven has been switched off while still above 150F, and the fan is running it down |
| B | Scotsman Prodigy series cubers | The letters the display shows in normal operation |
| Scotsman Flaker/nugget machines | Bin full, ice making paused | |
| BELT JAM | Lincoln Impinger Conveyor Ovens | The control cannot prove the conveyor is turning |
| BLOCKED DRAIN - RETRY | Pitco Solstice and SG/SSH fryers | Auto-filter fryers: the drain valve is not closing and the controller is not seeing the closed signal |
| BLUE OFF | Gaylord CG3-UVi water-wash ventilators | One or more UV lamps are not working |
| Gaylord CG3-UVi water-wash ventilators | No power reaching the UV ballast | |
| BLUE ON | Gaylord CG3-UVi water-wash ventilators | UV system in standby and not operating |
| BOOSTER LEVEL SENSOR | Hobart LXi/AM15 door dish machines | Booster pressure switch out of range |
| BREW TEMPERATURE TOO LOW | Bunn Axiom and Infusion Series ICB digital-control brewers | The brewer is refusing to start because the tank is below its ready temperature |
| C | Scotsman Prodigy series cubers | The letters the display shows in normal operation |
| Scotsman Flaker/nugget machines | Clean cycle running | |
| C4 | Pitco Solstice and SG/SSH fryers | Melt cycle in progress: not a fault |
| CA | True T-series and GDM reach-ins | External alarms of three severities, from a digital input |
| Perlick BBS/SDB and HP-series units | External alarms of three severities, from a digital input | |
| CALL SERVICE | Hobart LXi/AM15 door dish machines | Temperature probe fault on the LX40 family, equivalent to P1/P2/P3 |
| CALL SERVICE - ERR | Pitco Solstice and SG/SSH fryers | Auto-filter fryers: the blocked-drain lockout has been confirmed and the fryer will no longer operate |
| CAVITY TOO HOT | Southbend Convection Oven | Averaged cavity temperature reached 650F or higher |
| CCC | True T-series and GDM reach-ins | Probe open circuit and probe closed circuit respectively |
| Perlick BBS/SDB and HP-series units | Probe open circuit and probe closed circuit | |
| CHANGE WATER SOON | Hobart CLeN rack conveyor dish machines | Dirty Water Mode: the wash water is due a change |
| CHECK FITTINGS FOR LIME | Bunn Axiom and Infusion Series ICB digital-control brewers | The control has detected flow consistent with scale building up |
| CHECK FOR BAD CONNECTIONS | Bunn Axiom and Infusion Series ICB digital-control brewers | The temperature sensor circuit reads open |
| CHECK FUNNEL | Bunn Axiom and Infusion Series ICB digital-control brewers | The brewer will not start because the funnel is not right |
| CHECK SPRAYHEAD FOR LIME | Bunn Axiom and Infusion Series ICB digital-control brewers | The control has detected flow consistent with scale building up |
| CHECK SYSTEM | Delfield MCII Tempatrol, and 6000XL/6100XL reach-ins | Delfield's own wording is that a potentially serious problem has occurred |
| CHECK WATER LEVEL | Hobart CLeN rack conveyor dish machines | The tanks are not filling correctly |
| CHECK WIRE FOR SHORTS | Bunn Axiom and Infusion Series ICB digital-control brewers | The temperature sensor circuit reads shorted |
| CHI | Traulsen Intela-Traul reach-ins | High cabinet temperature: cabinet air has risen above the alarm band and stayed there |
| CLEAN CONDENSER | Delfield MCII Tempatrol, and 6000XL/6100XL reach-ins | A maintenance reminder on a 90-day timer, NOT a fault |
| CLEAN FILTER | Traulsen Intela-Traul reach-ins | Clean condenser: liquid line temperature reached 140F on R&A series, which Traulsen uses as a dirty-condenser signal |
| CLEAR CONVEYOR JAM | Hobart LXi/AM15 door dish machines | CL/CLe conveyor text alerts |
| Hobart CLeN rack conveyor dish machines | The conveyor motor OVERLOAD has tripped and shut the conveyor off | |
| CLO | Traulsen Intela-Traul reach-ins | Low cabinet temperature: cabinet air has fallen below the alarm band |
| CODE 3 | Ice-O-Matic CIM and Elevation cubers | Distributor guide numbering, not the board's own: usually described as a thermistor or multi fault code |
| CODE 5 | Ice-O-Matic CIM and Elevation cubers | Distributor guide numbering, not the board's own: usually described as a maximum length fill |
| CODE 33 | Convotherm easyTouch combi steamers (OES, OEB, OGS, OGB) | Steam generator will not reach its water level |
| CON | Beverage-Air WTR, UCR and HF cabinets | Condenser temperature is too high or too low |
| CONFIRM SHUT DOWN | Pitco Solstice and SG/SSH fryers | Scrolling confirmation prompt during a blocked-drain lockout |
| CONTROL OVER TEMP | Middleby Marshall PS640 and PS540 conveyor ovens | PS640: the control has overheated; Middleby gives the cause as clogged front filters |
| CONTROLS TOO HOT | Southbend Convection Oven | The control cavity, not the oven cavity, reached 176F or higher |
| COO | Heatcraft Beacon II Walk-In Systems | NOT FAULTS. These are the eight normal operating modes |
| COOL | Baxter OV500 rotating rack ovens | Cool Down mode is active, which is not a fault |
| D | Scotsman Prodigy series cubers | The letters the display shows in normal operation |
| Scotsman Flaker/nugget machines | Test mode active | |
| D1 | Turbo Air Reach-ins and Merchandisers | F-sensor and D-sensor malfunction respectively |
| DE-L | Hatco Flav-R-Savor holding cabinets | The water reservoir needs deliming |
| DEA | True T-series and GDM reach-ins | Defrost ended on TIME rather than on temperature |
| Perlick BBS/SDB and HP-series units | Defrost ended on TIME rather than on temperature | |
| DEF | True T-series and GDM reach-ins | Defrost in progress (LAE) |
| Beverage-Air WTR, UCR and HF cabinets | The unit is defrosting | |
| Heatcraft Beacon II Walk-In Systems | NOT FAULTS. These are the eight normal operating modes | |
| DEF ERR | Traulsen Intela-Traul reach-ins | Defrost error: defrost did not terminate on temperature during a 36 hour period |
| DEFROST | Delfield MCII Tempatrol, and 6000XL/6100XL reach-ins | A defrost cycle is running. Not a fault |
| DELIME RECOMMENDED | Hobart CLeN rack conveyor dish machines | Lime buildup is expected, worked out from your water hardness and how much final rinse water has been used |
| DLY | Heatcraft Beacon II Walk-In Systems | NOT FAULTS. These are the eight normal operating modes |
| DO | True T-series and GDM reach-ins | Door open alarm |
| DOOR AJAR | Delfield MCII Tempatrol, and 6000XL/6100XL reach-ins | A door is open, and after a delay the machine escalates |
| DOOR OPEN | Hobart LXi/AM15 door dish machines | CL/CLe conveyor text alerts |
| Hobart LXi/AM15 door dish machines | Door is open or not registering as closed | |
| Hobart CLeN rack conveyor dish machines | An inspection door is open | |
| Traulsen Intela-Traul reach-ins | Door open: a door has been open longer than the control allows | |
| DOR | Beverage-Air WTR, UCR and HF cabinets | Door is open |
| DR OP | Hobart LXi/AM15 door dish machines | Door is open or not registering as closed |
| DRAIN ERROR | Hobart LXi/AM15 door dish machines | Drain fault |
| DRAINING TURN OFF | Pitco Solstice and SG/SSH fryers | The controller believes the drain valve is open |
| E | Scotsman Prodigy series cubers | Self test failed at power-up, and nothing else will happen |
| Scotsman Flaker/nugget machines | Controller self test failed | |
| Stero SD3 door-type dish machines | The control keeps the most recent machine fault in service diagnostics even after a power cycle clears the display | |
| E-4 | Henny Penny OFE/OFG open fryers | Control board overheating |
| E-5 | Henny Penny OFE/OFG open fryers | Oil overheating |
| E-6A | Henny Penny OFE/OFG open fryers | Temperature probe OPEN circuit |
| E-6B | Henny Penny OFE/OFG open fryers | Temperature probe SHORTED |
| E-10 | Henny Penny OFE/OFG open fryers | High limit has tripped |
| E-15 | Henny Penny OFE/OFG open fryers | Drain switch failure, or the drain is open while the fryer is on |
| E-20A | Henny Penny OFE/OFG open fryers | Air pressure switch stuck CLOSED (gas models) |
| E-20B | Henny Penny OFE/OFG open fryers | Draft fan or air pressure switch stuck OPEN (gas models) |
| E-20C | Henny Penny OFE/OFG open fryers | Ignition modules not responding (gas models) |
| E-20D | Henny Penny OFE/OFG open fryers | Pilots not lit, or no flame sense (gas models) |
| E-31 | Henny Penny OFE/OFG open fryers | Fan jumper wire missing |
| E-41 TO E-46 | Henny Penny OFE/OFG open fryers | Programming failure |
| E-47 | Henny Penny OFE/OFG open fryers | Analog converter chip or 12-volt supply failure |
| E-48 | Henny Penny OFE/OFG open fryers | Input system error |
| E-54 | Henny Penny OFE/OFG open fryers | PCB component failure |
| E-70 | Henny Penny OFE/OFG open fryers | Faulty power switch, its wiring, or the I/O board |
| E-92 | Henny Penny OFE/OFG open fryers | The 24-volt fuse on the I/O board has opened |
| E0 | Hoshizaki FM-series flakers and F/FD modular flakers | Ice making water leak |
| Hobart LXi/AM15 door dish machines | Machine will not fill, or will not fill high enough. The cycle stops and the machine will not run | |
| E01 | Manitowoc Indigo/NXT/NEO cubers | Long freeze cycle |
| Alto-Shaam Combitherm combi ovens | Steam generator water fill fault | |
| Beverage-Air WTR, UCR and HF cabinets | Sensor S1 has failed, short or open. S1 is the air temperature probe | |
| E1 | Hoshizaki FM-series flakers and F/FD modular flakers | Low ice production |
| True T-series and GDM reach-ins | Cabinet temperature probe failure | |
| Perlick BBS/SDB and HP-series units | Probe reading out of range | |
| Beverage-Air WTR, UCR and HF cabinets | Sensor S1 has failed, short or open. S1 is the air temperature probe | |
| Hatco Flav-R-Savor holding cabinets | Air temperature sensor malfunctioning ON HOLDING CABINETS. On a Hydro-Heater it means something different: see below | |
| Turbo Air Reach-ins and Merchandisers | Depends entirely on which controller is fitted, and published sources contradict each other | |
| Heatcraft Beacon II Walk-In Systems | Sensor shorted, open or not installed: room, defrost and suction respectively | |
| E01.0 | Convotherm easyTouch combi steamers (OES, OEB, OGS, OGB) | Not enough water reaching the appliance |
| E02 | Manitowoc Indigo/NXT/NEO cubers | Long harvest cycle |
| Alto-Shaam Combitherm combi ovens | Control temperature high (CTP/CTC) | |
| Beverage-Air WTR, UCR and HF cabinets | Sensor S2 has failed, short or open. S2 is the evaporator coil probe used to terminate defrost | |
| E2 | Hoshizaki FM-series flakers and F/FD modular flakers | Float switch error |
| Hobart LXi/AM15 door dish machines | Machine will not fill, or will not fill high enough. The cycle stops and the machine will not run | |
| Hobart LXi/AM15 door dish machines | Fill did not complete: water failed to reach the tank float within 2.5 minutes (AM Select) | |
| True T-series and GDM reach-ins | Evaporator probe failure | |
| Perlick BBS/SDB and HP-series units | Defrost probe and third probe faulty | |
| Stero SD3 door-type dish machines | Water did not reach the float during fill within 150 seconds | |
| Beverage-Air WTR, UCR and HF cabinets | Sensor S2 has failed, short or open. S2 is the evaporator coil probe used to terminate defrost | |
| Hatco Flav-R-Savor holding cabinets | Humidity temperature sensor malfunctioning ON HOLDING CABINETS. On a Hydro-Heater it is the control probe: see below | |
| Turbo Air Reach-ins and Merchandisers | The clearest example of the contradiction, and worth checking carefully | |
| Heatcraft Beacon II Walk-In Systems | Sensor shorted, open or not installed: room, defrost and suction respectively | |
| E02.0 | Convotherm easyTouch combi steamers (OES, OEB, OGS, OGB) | Excessive temperature in the wiring space |
| E03 | Manitowoc Indigo/NXT/NEO cubers | Input power loss |
| Frymaster M3000 controller fryers | Temperature probe failure | |
| Alto-Shaam Combitherm combi ovens | Fan motor error (CTP/CTC) | |
| Beverage-Air WTR, UCR and HF cabinets | Sensor S3 has failed, short or open | |
| E3 | Hoshizaki FM-series flakers and F/FD modular flakers | Gear motor error or gear motor sensor circuit open |
| Hobart LXi/AM15 door dish machines | Machine will not fill, or will not fill high enough. The cycle stops and the machine will not run | |
| True T-series and GDM reach-ins | Auxiliary or display probe failure | |
| Perlick BBS/SDB and HP-series units | Defrost probe and third probe faulty | |
| Beverage-Air WTR, UCR and HF cabinets | Sensor S3 has failed, short or open | |
| Hatco Flav-R-Savor holding cabinets | The low water probe has not been satisfied and the heating elements are not yet submersed | |
| Heatcraft Beacon II Walk-In Systems | Sensor shorted, open or not installed: room, defrost and suction respectively | |
| E03.X | Convotherm easyTouch combi steamers (OES, OEB, OGS, OGB) | Frequency converter fault |
| E04 | Manitowoc Indigo/NXT/NEO cubers | High condenser temperature or water condenser fault |
| Frymaster M3000 controller fryers | High limit reading out of range | |
| Alto-Shaam Combitherm combi ovens | Lower fan motor error, two-motor models (CTP/CTC) | |
| Beverage-Air WTR, UCR and HF cabinets | Sensor S4 has failed, short or open | |
| E4 | Hoshizaki FM-series flakers and F/FD modular flakers | Abnormal high side pressure |
| Hobart LXi/AM15 door dish machines | Machine will not fill, or will not fill high enough. The cycle stops and the machine will not run | |
| Beverage-Air WTR, UCR and HF cabinets | Sensor S4 has failed, short or open | |
| Heatcraft Beacon II Walk-In Systems | Suction pressure transducer shorted, open or not installed | |
| E05 | Manitowoc Indigo/NXT/NEO cubers | High-pressure control opened |
| Frymaster M3000 controller fryers | High limit temperature exceeded | |
| Alto-Shaam Combitherm combi ovens | VFD communication failure (CTP/CTC) | |
| E5 | Hoshizaki FM-series flakers and F/FD modular flakers | Gear motor drive element error |
| Hobart LXi/AM15 door dish machines | Machine will not drain, or is filling too high and leaking from the door | |
| Heatcraft Beacon II Walk-In Systems | Outdoor temperature sensor shorted | |
| E06 | Frymaster M3000 controller fryers | Heating failure |
| Alto-Shaam Combitherm combi ovens | VFD communication failure, second drive (CTP/CTC) | |
| E6 | Hobart LXi/AM15 door dish machines | Control fault with no operator remedy published (AM Select) |
| Stero SD3 door-type dish machines | The float and temperature thermistors could not be detected at all | |
| Turbo Air Reach-ins and Merchandisers | Fault in the real-time clock | |
| Heatcraft Beacon II Walk-In Systems | Low superheat during cooling, held at 0F for two minutes | |
| E07 | Manitowoc Indigo/NXT/NEO cubers | Starving TXV or low refrigerant charge |
| E7 | Hobart LXi/AM15 door dish machines | Water sensors need cleaning |
| Heatcraft Beacon II Walk-In Systems | Compressor shutdown on a safety: high pressure, low pressure or oil pressure | |
| E08 | Manitowoc Indigo/NXT/NEO cubers | TXV fault |
| Frymaster M3000 controller fryers | ATO board error: the controller has lost contact with the automatic top-off board | |
| E8 | Hoshizaki FM-series flakers and F/FD modular flakers | Discharge pipe temperature fault |
| E09 | Manitowoc Indigo/NXT/NEO cubers | Flooding evaporator TXV fault |
| Frymaster M3000 controller fryers | Top-off pump not filling | |
| E9 | Heatcraft Beacon II Walk-In Systems | Multi-in to multi-out communication wiring error between evaporator boards |
| E10 | Manitowoc Indigo/NXT/NEO cubers | Flooding evaporator TXV fault |
| Frymaster M3000 controller fryers | Drain valve not open | |
| E11 | Manitowoc Indigo/NXT/NEO cubers | Refrigeration fault |
| Frymaster M3000 controller fryers | Drain valve not closed | |
| E12 | Manitowoc Indigo/NXT/NEO cubers | Curtain switch open more than 24 hours |
| Frymaster M3000 controller fryers | Return valve not open | |
| E13 | Frymaster M3000 controller fryers | Return valve not closed |
| E13.0 | Convotherm easyTouch combi steamers (OES, OEB, OGS, OGB) | Steam generator thermoelement, excessive temperature |
| E15 | Manitowoc Indigo/NXT/NEO cubers | Low ambient control fault |
| E16 | Manitowoc Indigo/NXT/NEO cubers | Remote condenser fault |
| Frymaster M3000 controller fryers | Filtration (AIF) probe error | |
| E17 | Frymaster M3000 controller fryers | Top-off (ATO) probe error |
| E19 | Manitowoc Indigo/NXT/NEO cubers | Ice thickness probe fault |
| E20 | Manitowoc Indigo/NXT/NEO cubers | Water system fault |
| Frymaster M3000 controller fryers | Invalid code location: the SD card was removed during a software upgrade | |
| E21 | Frymaster M3000 controller fryers | Filter pad procedure error |
| E21 TO E24 | Manitowoc Indigo/NXT/NEO cubers | Temperature sensor fault (T1 through T4) |
| E22 | Frymaster M3000 controller fryers | Oil in pan error |
| E25 | Manitowoc Indigo/NXT/NEO cubers | Bin level probe low sensor fault |
| Frymaster M3000 controller fryers | Recovery fault | |
| E26 | Manitowoc Indigo/NXT/NEO cubers | Bin level probe fault, medium (E26) and high (E27) sensor |
| E27 | Manitowoc Indigo/NXT/NEO cubers | Bin level probe fault, medium (E26) and high (E27) sensor |
| Frymaster M3000 controller fryers | Low temperature alarm: oil is roughly 35F below setpoint | |
| Turbo Air Reach-ins and Merchandisers | Sensor errors on specific inputs: S5, Sair and Saux respectively | |
| E27.0 | Convotherm easyTouch combi steamers (OES, OEB, OGS, OGB) | Safety temperature limiter, B8 thermoelement, excessive temperature |
| E28 | Manitowoc Indigo/NXT/NEO cubers | AUCS board not detected |
| Frymaster M3000 controller fryers | High temperature alarm | |
| E29 | Manitowoc Indigo/NXT/NEO cubers | USB communication or download fault |
| Turbo Air Reach-ins and Merchandisers | Sensor errors on specific inputs: S5, Sair and Saux respectively | |
| E30 | Manitowoc Indigo/NXT/NEO cubers | USB communication or download fault |
| Turbo Air Reach-ins and Merchandisers | Sensor errors on specific inputs: S5, Sair and Saux respectively | |
| E31 | Manitowoc Indigo/NXT/NEO cubers | Safe mode |
| E32 | Manitowoc Indigo/NXT/NEO cubers | RS485 communication fault |
| E33 | Manitowoc Indigo/NXT/NEO cubers | Touchscreen fault |
| E34 | Manitowoc Indigo/NXT/NEO cubers | Display fault |
| E36 | Manitowoc Indigo/NXT/NEO cubers | Checksum error |
| E37 | Manitowoc Indigo/NXT/NEO cubers | Watchdog event |
| E53 | Alto-Shaam Combitherm combi ovens | Fan motor temperature error (CTP/CTC) |
| E54 | Alto-Shaam Combitherm combi ovens | Lower fan motor temperature error, two-motor models (CTP/CTC) |
| E88 | Alto-Shaam Combitherm combi ovens | Gas burner failed to ignite |
| E89 | Alto-Shaam Combitherm combi ovens | Gas burner failed to ignite |
| E100 | Alto-Shaam Combitherm combi ovens | Maintenance reminder past due |
| E101 | Merrychef eikon speed ovens | Magnetron failed to energise |
| E102 | Merrychef eikon speed ovens | Heater turned ON WITHOUT REQUEST on the e2 family |
| E103 | Merrychef eikon speed ovens | Ambient overheat, 70C |
| E104 | Merrychef eikon speed ovens | Magnetron or cavity overheat |
| E105 | Alto-Shaam Combitherm combi ovens | Low water pressure or no water |
| Merrychef eikon speed ovens | Supply voltage high or low, OR supply frequency high or low, depending on the model | |
| E106 | Merrychef eikon speed ovens | Cavity reached 25C above setpoint after it had been controlling at temperature |
| E108 | Merrychef eikon speed ovens | QTS personality module failed, wrong module, or none fitted |
| E114 | Merrychef eikon speed ovens | Spare, not used |
| E115 | Merrychef eikon speed ovens | Convection fan failed |
| EA | True T-series and GDM reach-ins | External alarms of three severities, from a digital input |
| Perlick BBS/SDB and HP-series units | External alarms of three severities, from a digital input | |
| ED | Hobart LXi/AM15 door dish machines | Slow leak: the tank is losing water (AM Select) |
| Stero SD3 door-type dish machines | Slow leak: the machine refilled three times within 35 minutes of the initial fill | |
| EE | Hobart LXi/AM15 door dish machines | Final rinse never reached temperature: the booster did not hit setpoint within 8 minutes after initial fill (AM Select) |
| True T-series and GDM reach-ins | Power interruption during fast chill, clock settings lost, memory corruption | |
| Stero SD3 door-type dish machines | The booster did not reach temperature within eight minutes of the initial fill | |
| EF | Stero SD3 door-type dish machines | Severe internal control error |
| ELECTRICAL LOSS | Traulsen Intela-Traul reach-ins | Power loss: the unit lost power and the control is flagging it on return |
| ENERGY SAVE ACTIVE | Hobart CLeN rack conveyor dish machines | NORMAL. Idle mode after a period of no use, with heat OFF |
| ENERGY SAVING MODE 1 | Middleby Marshall PS640 and PS540 conveyor ovens | PS640: NORMAL OPERATION. The oven is in an energy saving state |
| ERROR 1 | Ice-O-Matic CIM and Elevation cubers | Maximum freeze or maximum harvest exceeded: Power LED quick flashing red |
| ERROR 2 | Ice-O-Matic CIM and Elevation cubers | Thermistor failure: Power LED slow flashing, shown in the off state only |
| ERROR 3 | Ice-O-Matic CIM and Elevation cubers | Maximum fill or maximum purge exceeded: Power LED red and Clean LED yellow, both quick flashing |
| F | Scotsman Prodigy series cubers | The letters the display shows in normal operation |
| Scotsman Flaker/nugget machines | Freeze mode: the machine is making ice | |
| Stero SD3 door-type dish machines | The control keeps the most recent machine fault in service diagnostics even after a power cycle clears the display | |
| F1 | TurboChef Tornado rapid cook ovens | Blower running status bad |
| Jackson NXP door-type dish machines | The booster is calling for heat with no water in it, which the control blocks to protect the element | |
| Turbo Air Reach-ins and Merchandisers | F-sensor and D-sensor malfunction respectively | |
| F2 | TurboChef Tornado rapid cook ovens | Cook temperature low |
| Jackson NXP door-type dish machines | A heater contactor is not switching off when it should | |
| F3 | TurboChef Tornado rapid cook ovens | Magnetron current low |
| Jackson NXP door-type dish machines | The machine could not fill | |
| F4 | TurboChef Tornado rapid cook ovens | Door monitor defective |
| Jackson NXP door-type dish machines | The machine is not receiving power correctly | |
| F5 | TurboChef Tornado rapid cook ovens | Magnetron over temperature |
| Jackson NXP door-type dish machines | The tank is not reaching temperature | |
| F6 | TurboChef Tornado rapid cook ovens | Electrical compartment temperature high |
| Jackson NXP door-type dish machines | Same fault as F1 but on the wash tank rather than the booster | |
| F7 | TurboChef Tornado rapid cook ovens | Thermocouple open |
| TurboChef Tornado rapid cook ovens | Two codes display on screen but are never counted, so the log understates what the oven has been doing | |
| Jackson NXP door-type dish machines | A heater contactor is not switching off when it should | |
| F8 | TurboChef Tornado rapid cook ovens | Heat low fault |
| Jackson NXP door-type dish machines | The machine could not fill | |
| F9 | Jackson NXP door-type dish machines | The machine is not receiving power correctly |
| F10 | Jackson NXP door-type dish machines | The tank is not reaching temperature |
| F11 | Jackson NXP door-type dish machines | A specific probe has failed |
| F12 | Jackson NXP door-type dish machines | A specific probe has failed |
| F13 | Jackson NXP door-type dish machines | The display board and the IO module have stopped talking |
| F14 | Jackson NXP door-type dish machines | The machine is not seeing the water pressure it needs |
| F15 | Jackson NXP door-type dish machines | The machine could not meet its sanitising requirement |
| F16 | Jackson NXP door-type dish machines | A low liquid level control fault |
| F17 | Jackson NXP door-type dish machines | The incoming water supply is too hot |
| FF | True T-series and GDM reach-ins | Power interruption during fast chill, clock settings lost, memory corruption |
| FILL TIME TOO LONG | Bunn Axiom and Infusion Series ICB digital-control brewers | The tank is taking too long to refill |
| FILL1 | Hobart LXi/AM15 door dish machines | Fill fault on the LX40 family, equivalent to E0/E2/E3/E4 |
| FILL2 | Hobart LXi/AM15 door dish machines | Fill fault on the LX40 family, equivalent to E0/E2/E3/E4 |
| FILL3 PRBLM | Hobart LXi/AM15 door dish machines | Fill fault on the LX40 family, equivalent to E0/E2/E3/E4 |
| FNL RINSE TEMP LOW | Hobart CLeN rack conveyor dish machines | Final rinse temperature is low (models with a booster) |
| FRYER WILL BECOME INOPERABLE | Pitco Solstice and SG/SSH fryers | Scrolling confirmation prompt during a blocked-drain lockout |
| GREEN OFF | Gaylord CG3-UVi water-wash ventilators | UV system in standby and not operating |
| Gaylord CG3-UVi water-wash ventilators | No power reaching the UV ballast | |
| GREEN ON | Gaylord CG3-UVi water-wash ventilators | One or more UV lamps are not working |
| H | Scotsman Prodigy series cubers | The letters the display shows in normal operation |
| HA | True T-series and GDM reach-ins | thi: highest temperature recorded in the LAE log. HA: live high temperature alarm on Dixell models |
| Perlick BBS/SDB and HP-series units | Dixell controller: maximum temperature alarm | |
| HEATING TIME TOO LONG | Bunn Axiom and Infusion Series ICB digital-control brewers | The tank is heating but not getting there |
| HELP | Garland MCO convection ovens | The control has a fault it cannot narrow down, and Garland lists three very different causes |
| HI | True T-series and GDM reach-ins | Cabinet high temperature alarm (LAE) |
| Vulcan VK/TR and ER/GR fryers | Oil at 415F or above | |
| Pitco Solstice and SG/SSH fryers | Oil at an unsafe temperature | |
| Beverage-Air WTR, UCR and HF cabinets | Cabinet temperature too warm | |
| HI TEMP | Frymaster M3000 controller fryers | Three separate over-temperature messages that are easy to confuse |
| Garland MCO convection ovens | The oven is more than 50F above its setpoint, and the heaters have been cut | |
| HIGH LIMIT FAILURE | Frymaster M3000 controller fryers | Three separate over-temperature messages that are easy to confuse |
| HIGH TEMP | Vulcan VK/TR and ER/GR fryers | Oil at 415F or above |
| HIGH TEMP ERROR | Middleby Marshall PS640 and PS540 conveyor ovens | PS640: thermocouple or PLC malfunction |
| HIGH TEMP! | Star SCT4000 Contact Toasters | Measured temperature is 75F (42C) or more ABOVE the set point |
| HIGH TMP | Vulcan VK/TR and ER/GR fryers | Oil at 415F or above |
| HOT HI-1 | Frymaster M3000 controller fryers | Three separate over-temperature messages that are easy to confuse |
| IGNITION FAILURE | Pitco Solstice and SG/SSH fryers | Burner failed to prove flame |
| IGNITION LOCKOUT | Vulcan VK/TR and ER/GR fryers | The fryer could not establish or prove a flame |
| L | Scotsman Prodigy series cubers | The letters the display shows in normal operation |
| Scotsman Flaker/nugget machines | Board locked, buttons ignored | |
| LA | True T-series and GDM reach-ins | tLo: lowest temperature recorded in the LAE log. LA: live low temperature alarm on Dixell models |
| Perlick BBS/SDB and HP-series units | Dixell controller: minimum temperature alarm | |
| LEA | Beverage-Air WTR, UCR and HF cabinets | Compressor run time too long |
| LO | True T-series and GDM reach-ins | Cabinet low temperature alarm (LAE) |
| Pitco Solstice and SG/SSH fryers | Oil below the ready temperature | |
| Beverage-Air WTR, UCR and HF cabinets | Cabinet temperature too cold | |
| LO H2O | Hatco Flav-R-Savor holding cabinets | The low water probe cannot detect water |
| LOC | True T-series and GDM reach-ins | Keypad locked (LAE) |
| Heatcraft Beacon II Walk-In Systems | Not a fault. The board is locked and settings cannot be changed | |
| LOC OUT | Baxter OV500 rotating rack ovens | Kosher lock-out: the oven fell below 150F and the control has disabled itself |
| LOW LIQ TEMP | Manitowoc Indigo/NXT/NEO cubers | Low ambient control fault |
| LOW TEMP! | Star SCT4000 Contact Toasters | After preheat, temperature stayed 50F (28C) or more BELOW set point for more than 15 minutes |
| LP FAIL | Lincoln Impinger Conveyor Ovens | Thermocouple failure, and the letters say WHICH SIDE |
| MELT | Vulcan VK/TR and ER/GR fryers | NOT A FAULT. The melt cycle is running, which is the first stage of heating solid shortening |
| MELT CYCLE | Vulcan VK/TR and ER/GR fryers | NOT A FAULT. The melt cycle is running, which is the first stage of heating solid shortening |
| NO OR LOW GAS SUPPLY | Vulcan VK/TR and ER/GR fryers | The fryer could not establish or prove a flame |
| O | Scotsman Prodigy series cubers | The letters the display shows in normal operation |
| Scotsman Flaker/nugget machines | Machine switched off at the controller | |
| OFF | True T-series and GDM reach-ins | Controller in standby, refrigeration off (LAE) |
| True T-series and GDM reach-ins | External alarms of three severities, from a digital input | |
| Perlick BBS/SDB and HP-series units | External alarms of three severities, from a digital input | |
| Garland MCO convection ovens | Not a fault. The oven is off and has cooled below 150F, so the fan relay has opened | |
| Heatcraft Beacon II Walk-In Systems | NOT FAULTS. These are the eight normal operating modes | |
| OP J1 | Hobart LXi/AM15 door dish machines | Control fault on the LX40 family, equivalent to E6 |
| OPD | Beverage-Air WTR, UCR and HF cabinets | Door is open |
| OPEN PROBE | Vulcan VK/TR and ER/GR fryers | Temperature probe circuit open |
| Southbend Convection Oven | The RTD temperature probe reads open | |
| P1 | Hobart LXi/AM15 door dish machines | Tank temperature probe out of range |
| True T-series and GDM reach-ins | Cabinet temperature probe failure | |
| Perlick BBS/SDB and HP-series units | Dixell controller: probe failure | |
| Stero SD3 door-type dish machines | Wash tank thermistor open or shorted | |
| P2 | Hobart LXi/AM15 door dish machines | Tank temperature probe out of range |
| True T-series and GDM reach-ins | Evaporator probe failure | |
| Stero SD3 door-type dish machines | Rinse thermistor open or shorted | |
| P3 | Hobart LXi/AM15 door dish machines | Rinse temperature probe out of range |
| True T-series and GDM reach-ins | Auxiliary or display probe failure | |
| Stero SD3 door-type dish machines | Booster thermistor open or shorted | |
| PDN | Heatcraft Beacon II Walk-In Systems | NOT FAULTS. These are the eight normal operating modes |
| PLEASE REPAIR | Bunn Axiom and Infusion Series ICB digital-control brewers | The last of the three lime warnings; flow is now badly restricted |
| PRBLM DR2 | Hobart LXi/AM15 door dish machines | Drain fault on the LX40 family, equivalent to E5 |
| PRESS STOP TO EXIT | Hobart CLeN rack conveyor dish machines | NORMAL. Idle mode after a period of no use, with heat OFF |
| PROB | Vulcan VK/TR and ER/GR fryers | Temperature probe circuit open |
| PROBE | Hobart LXi/AM15 door dish machines | Temperature probe fault on the LX40 family, equivalent to P1/P2/P3 |
| PROBE ERR - [TANK NAME] | Hobart CLeN rack conveyor dish machines | A fault with the LOWER FLOAT assembly in the tank named on the display |
| PROBE ERROR | Garland MCO convection ovens | The control is receiving no signal at all from the temperature probe |
| PROBE ERROR - FNLRNS | Hobart CLeN rack conveyor dish machines | A fault with the final rinse probe |
| PROBE FAIL | Lincoln Impinger Conveyor Ovens | The thermocouple has failed or become disconnected from the oven control |
| PROBE OP | Pitco Solstice and SG/SSH fryers | Digital controller: the temperature probe circuit reads open |
| PROBE OPEN | Vulcan VK/TR and ER/GR fryers | Temperature probe circuit open |
| PROBE SHORT | Vulcan VK/TR and ER/GR fryers | Temperature probe shorted |
| RED POWER OK | Hoshizaki KM crescent cubers, J series | Freeze-time correction for the THIRD time within 36 HOURS (large J-series models) |
| RED POWER OK LED | Hoshizaki KM crescent cubers, J series | FREEZE-TIME CORRECTION activated (large J-series models, board 2A7664-02) |
| RESET | Scotsman Prodigy series cubers | Control sequences worth knowing before assuming a board has failed |
| RESET REQUIRED | Hobart CLeN rack conveyor dish machines | The control needs a power reset |
| RMT CND TEMP | Manitowoc Indigo/NXT/NEO cubers | Remote condenser fault |
| RP FAIL | Lincoln Impinger Conveyor Ovens | Thermocouple failure, and the letters say WHICH SIDE |
| RTC | True T-series and GDM reach-ins | Power interruption during fast chill, clock settings lost, memory corruption |
| RTD OPEN! | Star SCT4000 Contact Toasters | The RTD temperature probe circuit is open |
| RTD SHORT! | Star SCT4000 Contact Toasters | The RTD temperature probe circuit is shorted |
| RUN ERR | Traulsen Intela-Traul reach-ins | Run error: the compressor has run continuously for more than 24 hours |
| SER | Heatcraft Beacon II Walk-In Systems | NOT FAULTS. These are the eight normal operating modes |
| SERVER NOT IN PLACE | Bunn Axiom and Infusion Series ICB digital-control brewers | The brewer will not start because it cannot see a server under the funnel |
| SERVICE 10 | Rational SCC series combi ovens | Self-clean water not pumped out |
| Rational iCombi Pro and Classic | SC automation malfunctioning (Classic title: SC-automatic failed). Cooking still possible | |
| SERVICE 11 | Rational SCC series combi ovens | Water metering sensor over-reading during steam generator fill |
| Rational iCombi Pro and Classic | Steam generator water intake malfunctioning (Classic: Water supply steam generator failed). Cooking still possible | |
| SERVICE 12 | Rational SCC series combi ovens | CDS sensor giving no output signal |
| Rational iCombi Pro and Classic | Water measurement system malfunctioning (Classic: Water volume measurement failed). Cooking still possible | |
| SERVICE 13 | Rational SCC series combi ovens | Steam generator not refilling during steam mode |
| Rational iCombi Pro and Classic | Steam generator water level detection malfunctioning (Classic: Water detection failed). ONLY HOT AIR MODE available | |
| SERVICE 14 | Rational SCC series combi ovens | Level electrode not recognising water |
| SERVICE 16 | Rational SCC series combi ovens | Software version too old for the function requested |
| SERVICE 17 | Rational SCC series combi ovens | External EEPROM faulty |
| Rational iCombi Pro and Classic | Unit model incorrect (Classic: Unit data failed). NO cooking | |
| SERVICE 20.1 | Rational iCombi Pro and Classic | A temperature probe is defective; the suffix says which one |
| SERVICE 21 | Rational SCC series combi ovens | Voltage or current monitoring error on the main control board |
| SERVICE 23 | Rational SCC series combi ovens | Solid state relay short circuit, steam |
| SERVICE 24 | Rational SCC series combi ovens | Solid state relay short circuit, hot air |
| SERVICE 25 | Rational SCC series combi ovens | No water flow detected during CleanJet |
| Rational iCombi Pro and Classic | Water quantity required by the iCareSystem is too low (iCombi Pro) | |
| SERVICE 26 | Rational SCC series combi ovens | Drain valve permanently closed |
| Rational iCombi Pro and Classic | Cleaning ball valve cannot find its OPEN (26) or CLOSED (27) position (iCombi Pro). NO cooking | |
| SERVICE 27 | Rational SCC series combi ovens | Drain valve will not close, CleanJet unavailable |
| Rational iCombi Pro and Classic | Cleaning ball valve cannot find its OPEN (26) or CLOSED (27) position (iCombi Pro). NO cooking | |
| SERVICE 28 | Rational SCC series combi ovens | Steam generator over temperature |
| SERVICE 28.1 | Rational iCombi Pro and Classic | Temperature limit exceeded: steam generator (28.1), cooking cabinet (28.2), or 28.4 as described |
| SERVICE 29 | Rational SCC series combi ovens | Control board over temperature |
| Rational iCombi Pro and Classic | Board temperature too high (Classic: Electric compartment too hot). NO cooking | |
| SERVICE 30 | Rational SCC series combi ovens | Running in emergency humidity control |
| Rational iCombi Pro and Classic | Humidity measurement incorrect (Classic: Humidity control failed). Cooking still possible | |
| SERVICE 31.1 | Rational iCombi Pro and Classic | Core temperature probe defective. Cooking possible WITHOUT the probe |
| SERVICE 31.X | Rational SCC series combi ovens | Core probe faulty, with the digit naming which probe |
| SERVICE 32.1-32.3 | Rational iCombi Pro and Classic | Gas burner faulty (gas units). NO cooking |
| SERVICE 32.X | Rational SCC series combi ovens | Ignition box faulty |
| SERVICE 33.X | Rational SCC series combi ovens | Repeated ignition resets without success |
| SERVICE 34.X | Rational SCC series combi ovens | Bus signal error, with the digit naming the device |
| Rational iCombi Pro and Classic | Internal data communication faulty; the suffix sets how serious it is | |
| SERVICE 35 | Rational SCC series combi ovens | Bus signal cannot be processed because the UltraVent is disconnected |
| SERVICE 36 | Rational SCC series combi ovens | Differential pressure sensor P1 faulty or out of range |
| Rational iCombi Pro and Classic | Differential pressure sensor defective. Cooking still possible | |
| SERVICE 37 | Rational SCC series combi ovens | Differential pressure sensor P1 faulty or out of range |
| Rational iCombi Pro and Classic | Differential pressure sensor defective. Cooking still possible | |
| SERVICE 40 | Rational SCC series combi ovens | Care Control fault |
| Rational iCombi Pro and Classic | Care liquid quantity required by the iCareSystem is too low (iCombi Pro). Cooking still possible | |
| SERVICE 41 | Rational iCombi Pro and Classic | Steam injection nozzle or pipe has SCALE. Steam injection not available |
| SERVICE 42.X | Rational iCombi Pro and Classic | Water supply faulty (Classic title: Solenoid valve failed); the suffix says where |
| SERVICE 43.X | Rational iCombi Pro and Classic | Internal water supply NOT CLOSING (Classic title: Solenoid valve failed). Only hot air mode |
| SERVICE 46.1 | Rational iCombi Pro and Classic | Water supply malfunctioning, steam generator (Classic title: Pump failed). Cooking still possible |
| SERVICE 47.1 | Rational iCombi Pro and Classic | Waste water pump defective. Cooking still possible |
| SERVICE 48.1 | Rational iCombi Pro and Classic | Circulating pump defective (iCombi Pro). Cooking still possible |
| SERVICE 49.1 | Rational iCombi Pro and Classic | Water supply faulty, care system (Classic title: Pump failed). Cooking still possible |
| SERVICE 50 | Rational iCombi Pro and Classic | Real time clock not initialised (iCombi Pro). Cooking still possible |
| SERVICE 51 | Rational iCombi Pro and Classic | Battery defective (iCombi Pro). Cooking still possible |
| SERVICE 52.1 | Rational iCombi Pro and Classic | Cooking cabinet lighting not working correctly (Classic: Cabinet light failed). Cooking still possible |
| SERVICE 60 | Rational iCombi Pro and Classic | Ignition box initialisation defective (gas units; Classic title: Gas system failed) |
| SERVICE 72 | Rational iCombi Pro and Classic | Activation temperature of a temperature probe exceeded (Classic: Safety temperature limiter has been triggered). NO cooking |
| SERVICE 110 | Rational iCombi Pro and Classic | Fault in the SC pump DURING AUTOMATIC CLEANING. NO cooking |
| SERVICE 120 | Rational iCombi Pro and Classic | Fault in water level recognition DURING AUTOMATIC CLEANING. NO cooking |
| SERVICE 121 | Rational iCombi Pro and Classic | Pour water 3 l (iCombi Classic). Only hot air mode |
| SERVICE 1017 | Rational iCombi Pro and Classic | USB stick error (iCombi Classic). Cooking still possible |
| SERVICE REQUIRED | Frymaster M3000 controller fryers | A fault has occurred that needs a technician, and the controller is asking whether to keep cooking |
| SHDN | Baxter OV500 rotating rack ovens | The safety alarm has shut the oven down after the probe read 570 to 600F for ten seconds |
| SHORTED PROBE | Vulcan VK/TR and ER/GR fryers | Temperature probe shorted |
| Southbend Convection Oven | The RTD temperature probe reads shorted | |
| SN1 | Traulsen Intela-Traul reach-ins | Sensor failure, shown on the display |
| SN2 | Traulsen Intela-Traul reach-ins | Sensor failure, shown on the display |
| SN3 | Traulsen Intela-Traul reach-ins | Sensor failure, shown on the display |
| SOLID LOW WATER LED | Follett Horizon Elite Chewblet ice machines | A soft error: the machine did not detect water within 60 seconds of power-on |
| SUMP LEVEL SENSOR | Hobart LXi/AM15 door dish machines | Sump pressure switch out of range |
| SYSTEM FAILURE | Pitco Solstice and SG/SSH fryers | Digital controller: the temperature probe circuit reads shorted |
| TEMP SENSOR OUT OF RANGE | Bunn Axiom and Infusion Series ICB digital-control brewers | The temperature sensor circuit reads open |
| Bunn Axiom and Infusion Series ICB digital-control brewers | The temperature sensor circuit reads shorted | |
| TEMPERATURE TOO LOW | Bunn Axiom and Infusion Series ICB digital-control brewers | Tank water has not reached ready temperature |
| TLO | True T-series and GDM reach-ins | tLo: lowest temperature recorded in the LAE log. LA: live low temperature alarm on Dixell models |
| TOO MUCH LIME PLEASE REPAIR | Bunn Axiom and Infusion Series ICB digital-control brewers | Scale has progressed far enough that brew volume is no longer reliable |
| TST | Heatcraft Beacon II Walk-In Systems | NOT FAULTS. These are the eight normal operating modes |
| TYPE 6 | Hoshizaki KM crescent cubers, J series | Control voltage LOW: 92 VAC plus or minus 5% or less. RESETS AUTOMATICALLY |
| TYPE 7 | Hoshizaki KM crescent cubers, J series | Control voltage HIGH: 147 VAC plus or minus 5% or more. RESETS AUTOMATICALLY |
| UHI | Beverage-Air WTR, UCR and HF cabinets | Line voltage too high |
| ULI | Beverage-Air WTR, UCR and HF cabinets | Line voltage too low |
| UNLOAD DISHES | Hobart CLeN rack conveyor dish machines | A rack has reached the end of the unload table and tripped the TABLE LIMIT SWITCH |
| UPDT-FAIL-USB-ERR | Baxter OV500 rotating rack ovens | A firmware or recipe update from USB failed |
| VENTLESS REFRIGERANT LO | Hobart CLeN rack conveyor dish machines | Ventless (VL) models: refrigerant is low |
| VENTLESS SHUTDOWN | Hobart CLeN rack conveyor dish machines | Ventless (VL) models: the ventless system has faulted |
| WARNING INACCURATE FLOW | Bunn Axiom and Infusion Series ICB digital-control brewers | Scale has progressed far enough that brew volume is no longer reliable |
| WARNING VERY LOW FLOW | Bunn Axiom and Infusion Series ICB digital-control brewers | The last of the three lime warnings; flow is now badly restricted |
| WATER CHANGE REQ'D | Hobart CLeN rack conveyor dish machines | Dirty Water Mode: the water must be changed |
| YELLOW BC LED ON | Hoshizaki KM crescent cubers, J series | BIN CONTROL OPEN: the machine believes the bin is full. Usually NOT a fault |
| YELLOW BC OPEN | Hoshizaki H-series stackable crescent cubers | NOT A FAULT. The bin control is open: the bin is full |
| YELLOW OFF | Gaylord CG3-UVi water-wash ventilators | UV system in standby and not operating |
| YELLOW ON | Gaylord CG3-UVi water-wash ventilators | One or more UV lamps are not working |
| Gaylord CG3-UVi water-wash ventilators | No power reaching the UV ballast |
Codes that are not in this list
Several makes report faults without a short code: Berkel counts flashes of a pilot light, Gaylord uses three status lights read in combination, Baxter uses beep patterns and an LED inside the control box, and Traulsen names alarm conditions. Those cannot be looked up by number and live on their brand pages instead.
Every meaning here is paraphrased from the manufacturer's own service documentation. Where a manufacturer's PDF lost a row or a column in extraction, the brand page says which part is missing rather than filling it with a guess.